A Bias-free Sampling and Collection Trap for Resting Mosquitoes

This CDC developed collection device is a small (approximately 1 cubic foot) open-sided container that attracts mosquitoes seeking a daytime resting location. The container is dark-colored and constructed of molded wood-fiber or recycled, high-density plastic. Mosquitoes that enter the dark space of the container are aspirated through a battery-powered fan into a collection receptacle. The receptacle is especially attractive to Culex and Anopheles mosquitos' vectors of West Nile Virus and malaria parasites, respectively.

Extension-Ladder Safety: Multimodal-feedback Indicator for Improved Ladder Positioning Safety and Efficiency

Improper positioning of an extension ladder frequently results in "ladder slide-outs," which are the most common cause of ladder-fall scenarios. This invention relates to an extension ladder positioning indicator which is easily installed in a ladder rung; provides multiple cues (visual, sound, and vibration) for rapidly identifying and positioning correct ladder inclination.

Improved Botulism, Botulinum Neurotoxin Type-E Diagnostics

CDC researchers have improved upon a prior, HHS patented mass spectrometry-based Endopep-MS assay that is able to rapidly detect and differentiate all seven botulinum neurotoxin (BoNT) types A to G. This current improvement comprises the addition of two optimized substrate peptides that increases the assay's sensitivity,relative to prior substrates, for botulinum neurotoxin type-E (BoNT/E) by greater than 100 fold.

Physiologic Sampling Pump Capable of Rapidly Adapting to User Breathing Rate

This CDC developed physiologic sampling pump (PSP) overcomes shortcomings of previous devices by the use of calibrated valves in conjunction with a constant speed pump. This novel approach obviates typical PSP inertia that inherently limits system response, functionality and accuracy. All prior PSP designs have attempted to follow a user's breathing pattern by changing pump speed, thereby altering sampling rate. In that approach, pump inertia will limit system response and function due to the time required to adjust speed.

Cylindrical Handle Dynamometer for Improved Grip-Strength Measurement

CDC researchers have developed an improved dynamometer device and method for measuring maximum hand grip force or grip-strength. Human test subjects were used in conducting experiments to evaluate the handle and to assess the measurement method. In contrast to the currently used "Jamar handle" grip strength dynamometer devices, the cylindrical handle proved to be able to determine the overall grip strength for a subject, as well as show the grip force distribution around the circumference of the handle.

Automated Microscopic Image Acquisition, Compositing and Display Software Developed for Applied Microscopy/Cytology Training and Analysis

Micro-Screen is a CDC developed software program designed to capture images and archive and display a compiled image(s) from a portion of a microscope slide in real time. This program allows for the re-creation of larger images that are constructed from individual microscopic fields captured in up to five focal planes and two magnifications. This program may be especially useful for the creation of data archives for diagnostic and teaching purposes and for tracking histological changes during disease progression.

Ultrasonic in situ Respirator Seal-Leakage Detection with Real-time Feedback Capabilities

This CDC invention entails methods and apparatuses for in situ testing seal integrity and improved operation of respiratory masks (respirators). A variety of external factors, such as individual face shape, user environment, mask age and material used to construct the respirator, can lead to device malfunction and failure to sufficiently protect a user. To address these limitations, this invention relies on ultrasonic wave detection to assess face seal quality and other potential leak paths, as needed.

Inexpensive, Personal Dust Detector Tube/Dosimeter Operating on a Gas Detector Tube Platform

This CDC developed dust detector tube is designed to provide inexpensive, short-term, time weighted average dust exposure data feedback directly to device users. This invention operates upon a conventional gas detector tube platform and can be used with any low volume pump that can electronically measure pump back pressure. The device consists of three sections: the first defines the size of the dust and removes moisture, the second uses a filter whose pressure differential corresponds with cumulative dust loading, and a final section employs a pressure transducer.

Auscultatory Training System and Telemedicine Tool with Accurate Reproduction of Physiological Sounds

This CDC developed auscultatory training apparatus includes a database of prerecorded physiological sounds (e.g., lung, bowel, or heart sounds) stored on a computer for playback. Current teaching tools, which utilize previously recorded sounds, suffer from the disadvantage that playback environments cause considerable distortion and errors in sound reproduction. For example, to those trainees using such systems, the reproduced respiratory sounds do not “sound” as if they are being generated by a live patient.

Air Quality Assurance: A Monitor for Continuous, Simultaneous Analysis of Atmospheric or Aerosolized Particulate Mixtures

This technology pertains to monitors for measuring the mass concentration of ambient particulate matter in an atmosphere containing both larger/coarser (e.g., respirable dust) and smaller/finer (sub-micrometer particles such as diesel particulate matter - DPM) particulate mixtures. The monitoring device can be configured for operation with a controller unit adapted to ionization sensor and/or light-scattering modules. The controller translates the sensor output signal into a quantifiable value, determining mass concentration of particulate matter within the ionization chamber.